• JDZ11-36 36kV Indoor voltage transformer
JDZ11-36 36kV Indoor voltage transformer
discuss personally
Model
JDZ11-36
Basic info
Brand Wone Store
Model NO. JDZ11-36 36kV Indoor voltage transformer
Rated frequency 50/60Hz
Primary voltage 35kV
Secondary voltage 110V
Series JDZ
Product Detail

Product Overview

36kV Indoor Single-Phase Epoxy Resin Type JDZ11-36 voltage transformer, is fully enclosed casting insulation structure,the primary winding, secondary winding and the annular core all coating in the epoxy resin casting, improve the filth and moisture resistance. The model adds the umbrella skin product desigh and increase external insulation creepage distance, is widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest voltage for equipment 40.5 kV.

Feature:

  • High-Precision Voltage Conversion: Uses high-quality silicon steel sheets and winding materials, with accurate voltage ratio and metering accuracy up to class 0.2, ensuring the accuracy of energy metering and monitoring data to meet the high-precision measurement needs of the power grid.

  • Compact Structural Design: Optimized for indoor spaces, its volume is 30% smaller than traditional similar products, saving substation floor space and suitable for installation in compact environments such as switch cabinets.

  • Excellent Insulation Reliability: Fully sealed with epoxy resin casting, reaching IP67 protection level, effectively resisting moisture, dust and dirt, and can operate stably for a long time in environments with relative humidity ≤95%.

  • Upgraded Safety Performance: Built-in overvoltage protection device, capable of withstanding 40kV lightning impulse voltage to prevent damage to equipment from system failures; partial discharge ≤10pC, reducing the risk of insulation aging.

  • Convenient Installation and Maintenance: With bottom outlet design, supporting horizontal or vertical installation, and self-contained mounting holes, it can be fixed with 4 M12 bolts, reducing on-site construction time by more than 50%.

Technical Data

  • Rated primary voltage: 33 kV or 34.5 kV or 35kV

  • Rated secondary voltage:100V,100/100V,100/220V

  • Rated voltage of residual voltage windings:100/ 3V 、110/ 3V、 115/ 3V、 120/ 3V

  • Burden power factor: cosΦ=0.8(lagging)

  • Standards: IEC60044-2.2003 or IEC61869-1&

Specification

Outline

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the